How-to’s
Section 5-1
272
Example 1
Only proportional gain has a set value, the Following Error is proportional to
the speed.
The parameter values for the example are:
/i
Motion Parameter values
P_Gain=131072
VFF_GAIN=0
Fn001=4
Note
The colours and scale of the oscilloscope for speed mode are as follows:
Red: MSPEED (Measured Axis speed). Units is 50 units/ms/division
Blue: FE (Following Error). Units is depending on the graph
Green: MPOS (Measured Axis position). 50000 units/division
Summary of Contents for trajexia CJ1W-MCH72
Page 69: ...Specifications Section 2 4 58...
Page 83: ...FINS commands Section 3 4 72...
Page 147: ...All BASIC commands Section 4 2 136 AXIS 1 AXIS 0...
Page 277: ...All BASIC commands Section 4 2 266...
Page 371: ...360 Index...
Page 373: ...362...