90H:
VASA[7..0]
91H:
VASA[15..8]
[Vertical ROI Start Line ROI_A]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_A[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_A[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_A.
Actual start line of the partial scanning ROI_A = this value + 1
92H:
VASB[7..0]
93H:
VASB [15..8]
[Vertical ROI Start Line ROI_B]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_B[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_B[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_B.
Actual start line of the partial scanning ROI_B = this value + 1
94H:
VASC[7..0]
95H:
VASC [15..8]
[Vertical ROI Start Line ROI_C]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_C[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_C[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_C.
Actual start line of the partial scanning ROI_C = this value + 1
96H:
VASD[7..0]
97H:
VASD [15..8]
[Vertical ROI Start Line ROI_D]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_D[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_D[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_D.
Actual start line of the partial scanning ROI_D = this value + 1
98H:
VASE[7..0]
99H:
VASE [15..8]
[Vertical ROI Start Line ROI_E]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_E[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_E[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_E.
Actual start line of the partial scanning ROI_E = this value + 1
9AH:
VASF[7..0]
9BH:
VASF [15..8]
[Vertical ROI Start Line ROI_F]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_F[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_F[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_F.
Actual start line of the partial scanning ROI_F = this value + 1
9CH:
VASG[7..0]
9DH:
VASG [15..8]
[Vertical ROI Start Line ROI_G]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_G[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_G[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_G.
Actual start line of the partial scanning ROI_G = this value + 1
9EH:
VASH[7..0]
9FH:
VASH [15..8]
[Vertical ROI Start Line ROI_H]
STC-CMB200PCL/CMC200PCL: Initial data: ROI_H[15..0] = 0, data range: 0 to 1,087
STC-CMB401PCL/CMC4401PCL: Initial data: ROI_H[15..0] = 0, data range: 0 to 2,047
Sets Vertical ROI Start Line ROI_H.
Actual start line of the partial scanning ROI_H = this value + 1