No.13S080-10
86
STC-CMB200PCL / STC-CMC200PCL / STC-CMB401PCL / STC-CMC401PCL
Specifications and Users guide
9. Actual Camera Setting & Technical Notes
Using the Trigger Signal through 6pin
1.Select the “[0]Trigger Shutter Mode(Long Exposure)” on Contiue/Trigger Shutter Mode Selection at
Standard tab through the control software(CLCtrl2).
2. Select the ”[0H] FIL_TRG/LVAL/FVAL_TRG_IN” on SP Pin Signal Selection at SP_Pin tab.
3. Input the trigger signal through Pin2. As for using the software, please refer to the
0.
Control
Software.
SP Pin Signal Selection Table
Pin No
5
4
3
2
Addr=F0
SP1
SP2
SP3
SP4
0
AfterTrigger FILTER
LVAL
FVAL
Trigger Input
1
F1h.0
F1h.1
F1h.2
F1h.3
2
CC1
T_EXP1
FRAME_REQ
HIGH in Exposure
3
CC1
T_EXP1
FRAME_REQ
FVAL
4
~
15
Reserved
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com