No.13S080-10
73
STC-CMB200PCL / STC-CMC200PCL / STC-CMB401PCL / STC-CMC401PCL
Specifications and Users guide
Command No.
Command Description
ACH:
VAHG[7..0]
ADH:
VAHG[15..8]
[Vertical ROI Effective Line ROI_G]
STC-CMB200PCL/CMC200PCL: Initial data: VAHG [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHG [15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
AEH:
VAHH[7..0]
AFH:
VAHG[15..8]
[Vertical ROI Effective Line ROI_H]
STC-CMB200PCL/CMC200PCL: Initial data: VAHH [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHH[15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com
Aegis
Electronic
Group,
Inc.