No.13S080-10
59
STC-CMB200PCL / STC-CMC200PCL / STC-CMB401PCL / STC-CMC401PCL
Specifications and Users guide
6.3 Edge preset trigger mode
In this trigger mode, the camera exposure starts at the rising edge of the trigger pulse or negative edge when
setting is “Trigger Polarity::Negative”, the camera exposure starts at the falling edge of the trigger pulse.
Exposure duration time is preset by the “Electrical Shutter” settings.
.
6.3.1 Edge preset trigger mode (V-Reset)
Note.1: The exposure time sets by the preset electronic shutter speed.
Note 2
.
The horizontal two lines noise is appeared on the image when Trigger signal is input while the image
output period. In this case, trigger input after video out or set usec unit on exposure time setting unit.
6.3.2 Edge preset trigger mode (Exposure timing)
Note.1: The trigger signal is removed by the filtering if the pulse width of the input trigger signal is less than 10us.
Please input the trigger signal has more than 1.0 us pulse width.
Note.2:
α
1(Exposure time offset) is different from using clock, TAP number.
Pulse Width
:
22[us]
Edge Preset
:
21[us]
Exposure
time
Internal VD
exposure
Trigger signal
(Rising edge)
Video out
*Note. 1
FVAL
Trigger signal
Exposure time
T1'
Exposure time: T1' = Preset electronic s
α1
Filtering *Note.1
1.0us
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com
Aegis
Electronic
Group,
Inc.