6.2 Pulse width trigger mode
In this trigger mode with positive polarity, the camera exposure starts at the rising edge of the trigger pulse and
stops at the falling edge of the trigger pulse. Therefore, In the case of the exposure positive polarity is selected, the
exposure periods are the high states of the trigger pulse.
6.2.1 Pulse width trigger mode (V-Reset)
Note.1: The exposure time sets by the pulse width of the trigger signal.
6.2.2 Pulse width trigger mode (Exposure timing)
Note.1: The trigger signal is removed by the filtering if the pulse width of the input trigger signal is less than 15us.
Please input the trigger signal has more than 1.0 us pulse width.
Note.2:
α
1(Exposure time offset) is different from using clock, TAP number.
Pulse Width
:
22[us]
Edge Preset
:
21[us]
Trigger signal
Exposure time
Exposure time: T1' = T1 +
α1 *Note2
T1
1.0us
Filtering *Note.1
T1'
Exposure
time
Internal VD
exposure
Trigger signal
(Positive
)
Video out
*Note. 1
FVAL