![background image](http://html1.mh-extra.com/html/omron/ns-series/ns-series_operation-manual_743542040.webp)
2-1
Starting the Ladder Monitor
38
Start the Ladder Monitor. Communications will start with the PLC and Ladder Monitor will
start. The port through which to monitor must be selected in the following cases.
•
To monitor the PLC connected to port B when PLCs are connected to both port A and
B
•
When the PLC to be monitored is not the one that was monitored the last time the
Ladder Monitor was used
•
When the PLC to be monitored is to be changed while using the Ladder Monitor
Use the following procedure to select the PLC to monitor.
1. Press the
Menu
Button in the Ladder Monitor screen and select
Change Host
from
the menu.
2. Select either serial
PortA
or
PortB
as the Comms. Method from the Change Host
dialog box and click the
OK
Button. If the
Change Host
Dialog Box is displayed, press
the
Connecting
Button.
Ladder Monitor When Connecting PT to PLC through Ethernet or
Controller Link Port on PT
Connect the Ethernet or Controller Link port on the PT to the PLC and enable
communications.
Start the Ladder Monitor and select the port using the following procedure.
1. Press the
Menu
Button on the Ladder Monitor screen and select
Change Host
from
the menu.
2. Select
Ethernet/CLK
as the
Comms. Method
from the
Change Host
Dialog Box and
click the
OK
Button.
3. Select the host name of the host connected via either the Ethernet or Controller Link
port and click the
OK
Button. The main menu screen will return. If the
Change Host
Dialog Box is displayed, press the
Connecting
Button.
Using the Ladder Monitor for the Controller Section of an NSJ
Controller
Start the Ladder Monitor and set the host using the following procedure.
1. Press
the
Menu
Button in the Ladder Monitor screen and select
Change Host
from
the menu.
2. The
Change Host
Dialog Box will appear. Select
Controller
as the Comm. Method
.
3.
Select the host name of the Controller Section for the
Host name
and click the
OK
Button. The Main Screen will appear. If the
Change Host
Dialog Box is displayed,
press the
Connecting
Button.
Summary of Contents for ns series
Page 2: ......
Page 15: ...NS Series Ladder Monitor OPERATION MANUAL LADDER MONITOR ...
Page 18: ......
Page 19: ...Section 1 Introduction ...
Page 31: ...Section 2 Installation ...
Page 43: ...Section 3 Basic Operation ...
Page 93: ...Section 4 Troubleshooting ...
Page 100: ...4 1 Troubleshooting 4 1 4 Error Message When Using Programming Console Function 98 ...
Page 101: ...Appendices ...
Page 106: ...A 2 Standard Models 104 ...
Page 107: ...NS Series Ladder Monitor OPERATION MANUAL I O Comment Extracting Tool ...
Page 109: ...Section 1 Introduction ...
Page 118: ...1 5 Specifications 12 ...
Page 119: ...1 5 Specifications Section 2 Installation ...
Page 121: ...2 1 Installing the I O Comment Extracting Tool Section 3 Basic Operation ...
Page 128: ...3 3 Uninstalling the I O Comment Extracting Tool 22 ...
Page 129: ...Appendix ...
Page 131: ......