3-3
Section
Unit Components
23
10. Make the settings in the System Setup using the CX-Programmer. (Create
the IP address table and IP router table.)
Refer to 3-9 System Setup, 3-10 Creating an IP Address Table, and 3-11
Creating an IP Router Table.
This step is required only in the following cases:
•
When using a method other than automatic generation for IP address con-
version. (Address conversion method, IP address table.)
•
When using the mail notification function.
•
When setting a subnet mask.
•
When setting an FTP login name and password.
•
When Ethernet is configured in multiple segments. (IP router table)
•
When Ethernet 4.28 is used (broadcast settings)
•
When the UDP port number for FINS is changed to something other than
the default setting (9600).
11. Check communications. (Use PING command and an internode test.)
Refer to 3-12 Checking Communications.
3-3
Unit Components
This section explains the Ethernet Unit’s components, settings, and LED indica-
tors. For details regarding the settings, refer to the individual explanations later
in this section.
3-3-1 Nomenclature
Indicators
Display the operating status
of the Unit.
Unit Number Switch
Used to set the Ethernet Unit’s unit
number in one digit hexadecimal.
Node Number Switches
Used to set the Ethernet Unit’s FINS node
number in two digits hexadecimal.
Ethernet Connector
Used to connect the Ethernet transceiver cable.
Power Supply Terminals
Used to connect an external 24-VDC
power supply for the transceiver.
Local IP Address Switches
Used to set the Ethernet Unit’s IP address
in eight digits hexadecimal.
Front
Back