7-3
Section
Using File Memory
141
7-2
Setting Login Names and Passwords
The default FTP login name is “CONFIDENTIAL” and no password is required.
Login is completed by typing only “CONFIDENTIAL”. A different login name and
a password can be set as required using the CPU Bus Unit Setup.
The following restrictions apply to login names and passwords.
•
The login name and password must consist of alphanumeric characters, hy-
phens, and/or underscores. They are not case sensitive.
•
A login name consists of 12 characters.
•
A password consists of 8 characters.
•
Always set a password when setting a new login name. The login name will not
be valid unless a password is set for it.
•
If a login name is not set or contains illegal characters, the default login name,
CONFIDENTIAL, must be used. No password is required and any password
that is set will be ignored.
A new login name and password can be set in the CPU Bus Unit Setup using the
CX-Programmer.
Note The CPU Bus Unit Setup is not contained in I/O memory, but in a parameter area.
The Setup cannot be written using instructions or edited as I/O memory. Settings
can be made only with the CX-Programmer.
Refer to the CX-Programmer User’s Manual for actual setting methods.
7-3
Using File Memory
There are two media that can be used to store files in memory for CS1-series
PCs:
•
Memory Cards
•
EM File Memory
CPU Unit
Memory Card
EM File
Memory
File
File
File
File
File Memory
Media
Memory type
Capacity
Model
File data recognized by CPU Unit
CS1-series
Flash
8 MB
HMC-EF861
•
Complete user program
Memory
memory
15 MB
HMC-EF171
•
Specified portions of I/O Memory
Cards
30 MB
HMC-EF371
•
Parameter area data (e.g. PC Setup)
EM File
Memory
RAM
Max. capacity of EM
Area in CPU Unit
(Largest EM Area:
832 KB in CS1H-CPU67)
All EM Area banks
from specified bank in
I/O Memory (specified
in PC Setup)
Parameter area data (e.g. PC Setup)
Setting Restrictions
Setting Method