9-3
Section
Troubleshooting Tables
132
Error
Meaning and corrective measures
Error
flags
SR 23500
to
SR 23507
Error log
(SIOU code,
details 1,
details 2)
Error
message
Unit indicators
Error
Meaning and corrective measures
Error
flags
SR 23500
to
SR 23507
Error log
(SIOU code,
details 1,
details 2)
Error
message
ERH
ERC
OPN
RUN
No END
Lit
OFF
Lit
OFF
NO END
INST
0360 Hex
00 Hex
F0 Hex
F0 Hex
SR 23511
END(01) is not written anywhere in
program.
Write END(01) at the final address of
the program.
Unit
system
error
(FALS)
Lit
OFF
Lit
OFF
SYS FAIL
FALS**
0360 Hex
00 Hex
FALS No. (1
to 99 BCD)
FALS No.
(1 to 99
BCD)
SR 23511
An FALS(07) instruction has been
executed in the program.
Check the FALS number to determine
the conditions that would cause
execution, correct the cause, and
clear the error.
Unit cycle
time
monitor
error
Lit
OFF
Lit
OFF
SYS FAIL
FALS9F
0360 Hex
00 Hex
F9 Hex
F9 Hex
SR 23511
The cycle time has exceeded the
FALS 9F Cycle Time Monitoring Time
(DM 6618).
Check the cycle time and adjust the
Cycle Time Monitoring Time if
necessary.
CPU Errors Resulting in Customizable Counter Unit Fatal Errors
Error
Unit indicators
Error
message
Error log
(SIOU code,
SR 23500
to
Error
flags
Meaning and corrective measures
RUN
OPN
ERC
ERH
me
age
(SIOU code,
details 1,
details 2)
to
SR 23507
flag
Unit
recognition
error
OFF
OFF
Lit
Lit
---
---
---
---
The Customizable Counter Unit is not
recognized as a Special I/O Unit by
the CPU Unit.
Try to power-up again.
Unit not
recognized
OFF
OFF
OFF
Lit
---
0006 Hex
08 Hex
00 Hex
---
---
The actual I/O tables do not agree
with the registered I/O tables.
Recreate the I/O tables in the CPU
Unit.
Unit
number
error
OFF
OFF
OFF
Lit
---
---
---
---
The unit number is not set correctly
or the same number has been set for
another Unit.
Correct the unit numbers and try to
power-up again.
Unit setting
read error
OFF
OFF
OFF
Lit
---
---
---
---
No response to a FINS command or
CPU settings could not be read.
Try to power-up again.
Bus error
OFF
OFF
OFF
Lit
---
---
---
---
The access right could not be
obtained.
Try to power-up again.
Summary of Contents for CS1 -
Page 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Page 2: ......
Page 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 146: ......
Page 166: ......