6-4
Section
AR Area
85
Address
Forced
set/reset
Controlled
by
Details
Function
Bits
AR 20
00 to 15
Pulse output 1 monitor
data
Range
comparison
result
The instruction
execution result that is
output when the CTBL
instruction is executed
for a range
comparison is stored
here.
Bits 00 to 15: ON for
each condition (from 1
to 16) that is satisfied.
OFF: Condition not
satisfied
ON: Condition
satisfied
Unit
Enabled
AR 21
00 to 15
Output bit
pattern
The output bit pattern
that is output when the
CTBL instruction is
executed for a range
comparison is stored
here.
Note: When more
than one condition is
satisfied, the logical
OR of all the output
patterns for satisfied
conditions is set.
AR 22
00 to 15
Pulse output 2 monitor
data
Range
comparison
result
Same as for pulse
output 1 monitor data.
AR 23
00 to 15
Output bit
pattern
Summary of Contents for CS1 -