7-6
Section
Pulse Outputs
98
Applicable Instructions
Instruction
Control
Description
(@)CTBL(63)
Range comparison
One range comparison executed.
(
)
(
)
Target value comparison table
registration and starting comparison
Target value comparison table registered and comparison
started.
Target value comparison table
registration
Target value comparison table registered.
(@)INI(61)
Starting comparison
Comparison started with previously registered target value
comparison table.
Stopping comparison
Target value comparison stopped.
Changing PV
PV of high-speed counter changed.
(@)PRV(62)
Reading high-speed counter PV
PV of high-speed counter read.
(
)
(
)
Reading high-speed counter rate of
change or frequency
Rate of change or frequency of high-speed counter read.
7-5-4 Internal Circuit Configurations
Phases A and B of Pulse Input
Phase A/B internal circuits
(1) 24-V input
(2) Pulse input 1: 5-V input, Pulse input 2: 12-V input
(3) Line-driver input
–
4.4 k
Ω
660
Ω
/1.64 k
Ω
(1)
(2)
(3)
Phase Z of Pulse Input
Phase Z internal circuits
(1) 24-V input
(2) Pulse input 1: 5-V input, Pulse input 2: 12-V input
(3) Line-driver input
–
3.0 k
Ω
440
Ω
/940
Ω
(1)
(2)
(3)
7-6
Pulse Outputs
7-6-1 Applicable Models
Model numbers
Functions
CS1W-HCP22
12 contact inputs, 8 contact outputs, 2 pulse inputs, 2 pulse outputs
7-6-2 Outline
The
CS1W-HCP22 Customizable Counter Unit provides 2 pulse outputs. The pulse out-
puts can be used for the following functions.
Summary of Contents for CS1 -
Page 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Page 2: ......
Page 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 146: ......
Page 166: ......