7.0 CALIBRATION MENU

Allow 5 minutes warm-up time (power on) before attempting calibration.

 In SETUP MENU, change standby time

to 10 minutes to stop the counter from switching off. When finished, reduce standby time to save battery power.
Calibration should be performed while the counter is running on battery power.
Place the counter on a flat, stable surface. Do not lean or make contact with the surface during calibration. Make
sure the room is free from excessive air drafts

—

  Press

|}

MENU

 key and select

OPTIONS

—

Select

CALIBRATION MENU

from the

OPTIONS MENU

7.1 CALIBRATING SCALES

To maintain accuracy the counter can be calibrated using a precise 100g weight

—

Select

CALIBRATE SCALES

from calibration menu

—

Start calibration and follow screen prompts (

ESC key can be used to abort calibration at any time)

—

On completion, select one of two options:

If any banknotes or coins were previously calibrated, select

USER CALIBRATED

, other-

wise select

FACTORY DEFAULT

7.2 CALIBRATING SCOOP

To use a different scoop to the one supplied, it needs to be calibrated first.

—

Select

CALIBRATE SCOOP

 from calibration menu

—

Start calibration and follow screen prompts

7.3 CALIBRATING PACKAGING ITEMS

Calibration requires between 10 and 100 samples of packaging items such as elastic bands, paper clips,

etc. Use only elastic bands with consistent width and diameter.

—

Select

CALIBRATE PACKAGE

 and the type of package to be calibrated

—

Select a sample quantity to be used for calibration

—

Select used quantity (1-12, number of packaging items used to make a package)

—

Start calibration and follow screen prompts

7.4 CALIBRATING BANKNOTES AND COINS

Please refer to a separate document:

http://www.noteandcoin.com/Downloads.html

8.0 PRINT FUNCTIONS

—

Press PRINT key to display the print options menu

Print Single

  Print running total for active denomination

Print Total

 

Print the grand total

Print Menu

 Press

˜

ENTER key to view saved counts data or PRINT key to print it

Use

…

 or

†

 key to change between coins and banknotes screen

Press PRINT key to individually print a full breakdown of coins or banknotes

Auto Print

 Press

˜

 ENTER key to toggle automatic print option

(Every time a count is registered, it will be printed automatically with current time & date)

9.0 POWER MANAGEMENT

The money counter can be operated from the internal battery or mains charger. The counter is not supplied with

a charger and can be charged from a standard 5V-USB charger used for smartphones, tablets and similar devic-

es via the USB cable supplied with the counter.

To prevent damage to personnel and equipment, use only reputable brand chargers like Apple, Samsung, etc.

To save battery power, banknote and coin counter will enter standby after a period of inactivity determined by

the STANDBY setting. Select shortest practical standby time from the OPTIONS MENU.

LCD backlight uses significant amount of battery power. The backlight will be reduced after a period of inactivity

determined by the BACKLIGHT setting. Select shortest practical backlight time from the OPTIONS MENU.

www.noteandcoin.com

Select required

DENOMONATION

Select required

COUNTING MODE

Press to

SWITCH ON

Press and hold to

SWITCH OFF

MAIN MENU

RESET MENU