6-4
Section
AR Area
84
Address
Forced
set/reset
Controlled
by
Details
Function
Bits
AR 18
08
Pulse Output 2 Status
Pulse Output
Completed Flag
Same as for Pulse
Output 1 Status.
Unit
Enabled
09
Number of
Pulses Specified
Flag
O
s
10
PLS2 Target
Frequency Not
Reached
11
Target
Comparison in
Progress
12
Independent
Pulse Output In
Progress
13
Positioning In
Progress (PLS2)
14
Accelerating/
Decelerating
15
Pulse Output In
Progress
AR 19
00
Pulse output 1
commands
PV Reset
OFF: Pulse output 1
PV not reset
ON: Pulse output 1 PV
reset
User
Enabled
01
Range
Comparison
Result Clear
OFF: The instruction
execution result
(AR 20) or the output
bit pattern (AR 21) that
is output when the
CTBL instruction is
executed for a range
comparison on the
pulse output PV is not
cleared.
ON: The instruction
execution result
(AR 20) or the output
bit pattern (AR 21) that
is output when the
CTBL instruction is
executed for a range
comparison on the
pulse output PV is
cleared.
02 to 07
(Reserved by system.)
08
Pulse output 2
d
PV Reset
Same as for pulse
1
d
09
commands
Range
Comparison
Result Clear
output 1 commands.
10 to 15
(Reserved by system.)
Summary of Contents for CS1 -
Page 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Page 2: ......
Page 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 146: ......
Page 166: ......