58
FFT Spectrum Analyzer Menu
The RTA menu allows you to monitor the same sources as those mentioned in the Oscilloscope
menu section.
The Delay control works the same here as it does previous and subsequent display sections.
The Resolution control selects the number of frequency bands into which the audio is
divided. 1x resolution gives you a refresh rate of approximately 48 frames per second and a
frequency resolution sufficient for viewing the entire audio spectrum. 8x resolutions gives
you a refresh rate of approximately 6 frames per second, but a much finer frequency
resolution.
The Decay Rate control adjusts how quickly the display will fall after a peak is displayed.
Lower settings are the slowest, while the highest setting is instantaneous.
The Peak Hold control enables or disables the ability to indicate and hold the highest peak
achieved. Peak Hold is displayed in the dark green background layer.
The X-‐Center control centers the display at the selected frequency.
The X-‐Width control sets the displayed frequency range in kHz.
The Y-‐Center control centers the display vertically around the selected level in dB.
The Y-‐Range control sets the displayed level range in dB.
The dB Scale Position control allows you to move the dB scale horizontally to a different place in the
display. Advancing the control completely to the right places it in front of the graph at all times.
Summary of Contents for Omnia.9
Page 2: ......
Page 8: ......
Page 103: ...95 Input Output Overview...
Page 104: ...96 MPX Input MPX Output...
Page 105: ...97 MPX Patch Point...
Page 106: ...98 Pre emphasis Patch Point...
Page 107: ...99 Undo...
Page 108: ...100 Input AGC WB AGC1...
Page 109: ...101 WB AGC3 Post Multiband...
Page 110: ...102 WB AGC3 Bass Wideband...
Page 111: ...103 WB AGC3 Bass Only...
Page 112: ...104 Multiband Processing...
Page 113: ...105 Speaker Controller...