1-5-37
C6050
Fuser thermistor abnormal tempera-
ture detection
• During copying, the temperature at the
heat roller lower than 120
°
C/248
°
F is
detected continuously for 5 s.
Installation defec-
tiveness on fuser
thermistor M and
S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Operation on fuser
thermostat.
Check for continuity. If none, replace the
fuser thermostat.
Installation defec-
tiveness on fuser
heater L, M or S.
Check the mounting state of the fuser ther-
mistor L, M and S. If any problem is found,
repair it.
Broken fuser
heater L, M and S
wire.
Check for continuity. If none, replace the
fuser heater L, M and S (see page 1-6-76).
C6400
Zero-cross signal error
• The main PWB does not detect the
zero-crossing signal (Z CROSS SIG)
for 5 s.
Poor contact in the
connector termi-
nals.
Check the connection of connectors YC11
on the main PWB and YC6 on the DC power
source PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective DC
power source
PWB.
Check if the zero-crossing signal is output
from YC6-3 on the DC power source PWB.
If not, replace the DC power source PCB.
Defective main
PWB.
Replace the main PWB if C6400 is detected
while YC6-3 on the DC power source PWB
outputs the zero-crossing signal.
C7200
Broken internal thermistor wire
• The thermistor output value is 4.5 V or
more.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC23 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective develop-
ing humidity sen-
sor.
Replace the developing humidity sensor.
C7210
Short-circuited internal thermistor
• The thermistor input value is 0.5 V or
less.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC23 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective develop-
ing humidity sen-
sor.
Replace the developing humidity sensor.
C7300
Toner hopper problem
• Toner level is not detected when toner
empty is detected.
Defective toner
level detection sen-
sor.
Replace the toner level detection sensor.
Poor contact in the
toner level detec-
tion sensor con-
nector terminals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
C7800
Broken external thermistor wire
• The thermistor output value is 4.5 V or
more.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC13 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective humidity
sensor.
Replace the humidity sensor.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Y104350-7 Sevice Manual
Summary of Contents for d-Copia 600
Page 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Page 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Page 10: ......
Page 34: ......
Page 83: ...This page is intentionally left blank...
Page 314: ...This page is intentionally left blank...
Page 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...