1-4-37
U161
Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set and press the start key. The screen for setting is displayed.
Setting: PAGE1
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
The respective temperatures are to be set such that 2ND TEMP >= 1ST TEMP.
3. Press the start key. The value is set.
Setting: PAGE2
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
3. Press the start key. The value is set.
Maintenance
item No.
Description
Display
Description
PAGE1
Control temperature during copying, primary stabilization fuser temperature, sec-
ondary stabilization fuser temperature, aging time after secondary stabilization,
control temperature adjustment in duplex copying and time from power on to stabi-
lization of fusing.
PAGE2
Control temperature adjustment in duplex copying using A4/Letter/B5 size paper,
control temperature adjustment using small size paper and control temperature
adjustment when the fuser heater temperature goes low.
Display
Setting
Setting range Default setting
CONT TEMP
Control temperature during copying
100 to 230
(
°
C)
200 (80 cpm)
195 (60 cpm)
1ST TEMP
Primary stabilization fuser temperature
100 to 200
(
°
C)
175 (120 V)
140 (220-240 V)
2ND TEMP
Secondary stabilization fuser temperature 100 to 230
(
°
C)
185
TIME
Aging time after secondary stabilization
0 to 255 (s)
60
DUPLEX
Control temperature adjustment in duplex
copying
-30 to 0 (
°
C)
-10
WARM UP TIME
Time from power on to stabilization of
fusing
0 to 255 (s)
26
Display
Setting
Setting range Default setting
DUPLEX2
Control temperature adjustment in duplex
copying using A4/Letter/B5 size paper
-30 to 0 (
°
C)
0
SMALL
Control temperature adjustment using
small size paper
-30 to 0 (
°
C)
0
SPEED DOWN
Control temperature adjustmen when the
fuser heater temperature goes low
-10 to 10 (
°
C)
0
Y104350-7 Sevice Manual
Summary of Contents for d-Copia 600
Page 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Page 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Page 10: ......
Page 34: ......
Page 83: ...This page is intentionally left blank...
Page 314: ...This page is intentionally left blank...
Page 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...