1-6-80
(9) Detaching and refitting the heat roller separation claws
Follow the procedure below to replace the heat roller separation claws.
Procedure
1. Open the eject section.
2. Remove the screw and then remove the
metal fitting from the eject section.
3. Remove two screws and then remove the
eject holder from the eject section.
Figure 1-6-157
4. Remove the eject guide from the eject sec-
tion.
Figure 1-6-158
5. Loosen the screw and then slide the retainer
in the direction of arrow.
Figure 1-6-159
Eject holder
Metal fitting
Eject guide
Retainer
Eject guide
Service Manual Y104350-7