1-6-98
(4) Detaching and refitting the image formation fan filter
Follow the procedure below to replace the image formation filter.
Procedure
1. Remove the image formation fan cover
while pushing the lever.
Figure 1-6-190
2. Remove the image formation fan filter from
the image formation fan cover.
3. Replace the image formation fan filter and
attach the filter to the image formation fan
cover.
4. Refit the image formation fan cover.
Figure 1-6-191
Image formation
fan cover
Lever
Image formation
fan filter
Image formation
fan cover
Service Manual Y104350-7