362
XANTREX FREEDOM XC PRO INVERTER
Basic Installation Procedures
975-0799-01-01
29
AC wiring must be sized appropriately using conductors with
insulation rated at least 75 °C to carry full load current on the input
and output AC circuits in accordance with the electrical codes or
regulations applicable to your installation.
Table 8
is based on the
U.S. National Electrical Code and the Canadian Electrical Code,
assuming two-conductor-plus-ground cable, using 75 °C wiring, at
an ambient temperature of 30 °C. Other codes and regulations
may be applicable to your installation.
Required Breaker
Size (A)
Required Wire
Size (AWG)
Freedom XC
PRO 2000
30 A maximum
20 A maximum through
a GFCI
10 AWG
Freedom XC
PRO 3000
50 A maximum
20 A maximum through
a GFCI
6 AWG
Table 8 Required AC wire size vs. required breaker rating
The AC input terminal is located inside the unit through the front
panel’s ½" trade-size hole (or ¾" trade-size knockout) and is
labeled properly as
AC IN
or
AC INPUT
. The unit comes with
spring clamp-type terminals where individual wires can be
attached securely.
NOTICE
EQUIPMENT DAMAGE
Make sure the wires are connected properly. The AC wiring
terminal blocks are split into input and output sections.
Failure to follow these instructions can result in equipment
damage.
When making the AC input and AC output connections, observe the
correct color code for the appropriate AC wire, as described in
Table
9
below.
Color
AC Wire
Black/Red/Brown
Line
White/light blue
Neutral
Green, green/yellow, or bare
copper
Ground
Table 9 Color codes for typical AC wiring
Basic Installation Procedures
30
Freedom XC PRO Owner's Guide
NOTICE
REVERSE POLARITY DAMAGE
Make sure the wires are connected properly. Improper connections
(connecting a line conductor to a neutral conductor, for example)
will cause the Freedom XC PRO to malfunction and may
permanently damage the inverter/charger. Damage caused by a
reverse polarity connection is not covered by your warranty.
Failure to follow these instructions can result in equipment
damage.
Wiring Knockouts
When installing wires to the AC terminals, the AC input and output
holes are provided to accommodate ½" trade-size strain relief
clamps. If larger cables and strain relief clamps are needed,
remove the ¾" trade-size knockout rings.
Make sure to seal the open knockout holes with the supplied
knockout plugs by placing the plugs and firmly pressing them into
the holes.
NOTICE
EQUIPMENT DAMAGE
Install the supplied AC knockout plugs over the knockout holes
when not used for wiring to prevent objects and other material from
entering the unit.
Failure to follow these instructions can result in equipment
damage.
AC Input Connections
To make a permanent connection to existing AC wiring:
1. Ensure AC and DC power sources are turned off.
2. Install the required circuit breaker in the AC distribution
panel supplying AC power to the unit.
3. Remove the wiring compartment cover by loosening the
captive nut panel screw and lifting the cover up and out.
WARNING
ELECTRIC SHOCK HAZARD
Use a screwdriver to loosen the captive nut panel screw.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Summary of Contents for LEGACY ELITE 2022
Page 2: ......
Page 22: ...22 AUTO DRAIN...
Page 149: ...149 KEYLESS ENTRY DOOR LOCK...
Page 162: ...162 Page 11 2017 Nature s Head Inc INSTALLATION Venting NATURE S HEAD COMPOSTING TOILET...
Page 204: ...204 LIFELINE AGM BATTERIES 2 2 Battery with Cut Away View...
Page 205: ...205 LIFELINE AGM BATTERIES 2 3 Terminal Types...
Page 363: ...363 XANTREX FREEDOM XC PRO INVERTER 1 N L G G L N G L N 2 1 3 4 5...
Page 364: ...364 XANTREX FREEDOM XC PRO INVERTER N L G G L N G L N 2 1 3 4 5...
Page 365: ...365 XANTREX FREEDOM XC PRO INVERTER 1 2 3...
Page 366: ...366 XANTREX FREEDOM XC PRO INVERTER 1 2 3 4 5 7 6...
Page 367: ...367 XANTREX FREEDOM XC PRO INVERTER...
Page 369: ...369 XANTREX FREEDOM XC PRO INVERTER sensor cable connector...
Page 370: ...370 XANTREX FREEDOM XC PRO INVERTER BTS Battery cable neg battery terminal BTS Battery case...
Page 371: ...371 XANTREX FREEDOM XC PRO INVERTER...
Page 372: ...372 1 11 13 12 3 5 4 10 8 9 7 6 2 XANTREX FREEDOM XC PRO INVERTER...
Page 375: ...375 XANTREX FREEDOM XC PRO INVERTER...
Page 376: ...376 XANTREX FREEDOM XC PRO INVERTER...
Page 377: ...377 XANTREX FREEDOM XC PRO INVERTER...
Page 378: ...378 XANTREX FREEDOM XC PRO INVERTER...
Page 379: ...379 XANTREX FREEDOM XC PRO INVERTER...
Page 380: ...380 XANTREX FREEDOM XC PRO INVERTER...
Page 381: ...381 XANTREX FREEDOM XC PRO INVERTER...
Page 382: ...382 XANTREX FREEDOM XC PRO INVERTER...
Page 384: ...384 XANTREX FREEDOM XC PRO INVERTER...
Page 385: ...385 XANTREX FREEDOM XC PRO INVERTER...
Page 386: ...386 XANTREX FREEDOM XC PRO INVERTER...
Page 387: ...387 XANTREX FREEDOM XC PRO INVERTER...
Page 388: ...388 XANTREX FREEDOM XC PRO INVERTER...
Page 389: ...389 XANTREX FREEDOM XC PRO INVERTER...
Page 390: ...390 XANTREX FREEDOM XC PRO INVERTER...
Page 391: ...391 XANTREX FREEDOM XC PRO INVERTER...
Page 392: ...392 XANTREX FREEDOM XC PRO INVERTER...
Page 393: ...393 267 288 9 15 290 296 305 0 9 69 336 396 406 0 27 122 125 XANTREX FREEDOM XC PRO INVERTER...
Page 394: ...394 XANTREX FREEDOM XC PRO INVERTER...
Page 395: ...395 XANTREX FREEDOM XC PRO INVERTER...
Page 396: ...396 XANTREX FREEDOM XC PRO INVERTER...
Page 397: ...397 XANTREX FREEDOM XC PRO INVERTER...
Page 408: ......
Page 409: ......