APPENDIX A – Error Codes
If the appliance malfunctions, LED 2 (refer to “Overview / Designation of parts” on page 2) will flash to indicate the malfunction.
There are short and long intervals of flashing. The flashing will repeat every 3 seconds.
1. Note the flashing intervals and check the list below.
2. Reset the appliance:
– Switch off the appliance. / – Wait 5 seconds / –Switch the appliance on again.
3. If an error code is still displayed, contact an authorized Truma service center.
Error
code
Flash code
s =short = 0
l = long = 1
Error
Description
1
s,s,s,s,s,s,s,l Flame not detected
There is a flame-detection error at the burner because the flame was not de-
tected after release of gas and ignition.
Important:
The system indicates this error only after three attempts at intervals
of approximately 30 seconds.
2
s,s,s,s,s,s,l,s Error at over temperature
switches (EOS, BOS)
The exhaust over temperature switch (EOS) or burner over temperature switch
(BOS) is open/unplugged.
3
s,s,s,s,s,s,l,l
Error at exhaust pressure
switch (EPS)
The EPS did not close when the flue fan was actuated because the fan did not
push enough air through the exhaust channel. A cause could be, e.g., blocking
of the exhaust channel or a faulty switch.
OR
The EPS is closed even though the flue fan is not running. Cause is a defective
EPS or flue fan.
4
s,s,s,s,s,l,s,s Error at water over tem-
perature switch (WOS)
The WOS opened at a water temperature of over 185 °F (85 °C).
5
s,s,s,s,s,l,s,l
Flame detected at incor-
rect time
There is an error in flame detection of the burner because the flame was detected
– before ignition or
– before the release of gas or
– after the gas was switched off.
6
s,s,s,s,s,l,l,s
Error in the safety circuit
for gas valve
There is a heating request but gas cannot be released.
One of the switches WOS, EOS, BOS, EPS is open/unplugged.
7
s,s,s,s,s,l,l,l
Error of burner MCU
internal RAM
Error detected in the burner MCU’s internal safety monitoring feature (safety
variables are no longer correct or RAM/STACK was overwritten by mistake).
9
s,s,s,s,l,s,s,l
Malfunction of water
outlet temperature sensor
WOT
Water outlet temperature sensor WOT
– has a short circuit or
– is open/unplugged.
10
s,s,s,s,l,s,l,s
Error in the safety circuit
There is a heating request but gas is not released because a valve-actuation
signal was not activated.
11
s,s,s,s,l,s,l,l
Error of MCU watchdog
gas release
There is a heating request but the MCU watchdog does not release the gas
path.
12
s,s,s,s,l,l,s,s
Internal error
13
s,s,s,s,l,l,s,l
Short circuit shut-off valve Short circuit detection in the gas valve (shut-off part) detected a current
> 1000 mA and shut off.
16
s,s,s,l,s,s,s,s Malfunction of the MCU
Internal error of the control unit.
20
s,s,s,l,s,l,s,s
Malfunction of water inlet
temperature sensor WIT
Water inlet temperature sensor WIT
– has a short circuit or
– is open/unplugged or
– the temperature of the sensor is colder than 14 °F (-10 °C).
21
s,s,s,l,s,l,s,l
Malfunction of circulation
line temperature sensor
WCT
Circulation line temperature sensor WCT
– has a short circuit or
– is open/unplugged or
– the temperature of the sensor is colder than 14 °F (-10 °C).
22
s,s,s,l,s,l,l,s
Malfunction of gas valve,
modulation section
Error at gas valve, modulation level, because
- the modulator has a short circuit or
- is open/unplugged.
23
s,s,s,l,s,l,l,l
Voltage is too high
The main power supply’s voltage detector measured a voltage level of >16.4 V.
24
s,s,s,l,l,s,s,s
Voltage is too low
The main power supply’s voltage detector measured a voltage level of <10 V.
25
s,s,s,l,l,s,s,l
Flue fan current con-
sumption error
The current detector for the flue fan has measured a current outside the permit-
ted limits.
26
s,s,s,l,l,s,l,s
Circulation pump current
consumption error
The current detector at the circulation pump has measured a current outside the
permitted limits.
27
s,s,s,l,l,s,l,l
Water circulation pump is
running dry.
The circulation pump does not generate water flow. The water system may not
be filled or not sufficiently vented.
The circulation pump tries (20 times) to generate a water flow every 30 s (if
successful, the error is reset).
28
s,s,s,l,l,l,s,s
Too low gas pressure.
Gas supply (in vehicle) to the appliance insufficient.
29
s,s,s,l,l,l,s,l
Too high heat power
required.
You are trying to use more hot water than the appliance can supply.
30
s,s,s,l,l,l,l,s
Risk of freezing.
Temperature in the appliance below 27 °F (3 °C).
31
s,s,s,l,l,l,l,l
Decalcification finished.
–
32
s,s,l,s,s,s,s
Current too low.
Current in the antifreeze kit too low (e.g. cable break).
33
s,s,l,s,s,s,s,l
Current too high.
Current in the antifreeze kit too high (e.g. short circuit).
TRUMA AQUAGO COMFORT WATER HEATER
Summary of Contents for LEGACY ELITE 2022
Page 2: ......
Page 22: ...22 AUTO DRAIN...
Page 149: ...149 KEYLESS ENTRY DOOR LOCK...
Page 162: ...162 Page 11 2017 Nature s Head Inc INSTALLATION Venting NATURE S HEAD COMPOSTING TOILET...
Page 204: ...204 LIFELINE AGM BATTERIES 2 2 Battery with Cut Away View...
Page 205: ...205 LIFELINE AGM BATTERIES 2 3 Terminal Types...
Page 363: ...363 XANTREX FREEDOM XC PRO INVERTER 1 N L G G L N G L N 2 1 3 4 5...
Page 364: ...364 XANTREX FREEDOM XC PRO INVERTER N L G G L N G L N 2 1 3 4 5...
Page 365: ...365 XANTREX FREEDOM XC PRO INVERTER 1 2 3...
Page 366: ...366 XANTREX FREEDOM XC PRO INVERTER 1 2 3 4 5 7 6...
Page 367: ...367 XANTREX FREEDOM XC PRO INVERTER...
Page 369: ...369 XANTREX FREEDOM XC PRO INVERTER sensor cable connector...
Page 370: ...370 XANTREX FREEDOM XC PRO INVERTER BTS Battery cable neg battery terminal BTS Battery case...
Page 371: ...371 XANTREX FREEDOM XC PRO INVERTER...
Page 372: ...372 1 11 13 12 3 5 4 10 8 9 7 6 2 XANTREX FREEDOM XC PRO INVERTER...
Page 375: ...375 XANTREX FREEDOM XC PRO INVERTER...
Page 376: ...376 XANTREX FREEDOM XC PRO INVERTER...
Page 377: ...377 XANTREX FREEDOM XC PRO INVERTER...
Page 378: ...378 XANTREX FREEDOM XC PRO INVERTER...
Page 379: ...379 XANTREX FREEDOM XC PRO INVERTER...
Page 380: ...380 XANTREX FREEDOM XC PRO INVERTER...
Page 381: ...381 XANTREX FREEDOM XC PRO INVERTER...
Page 382: ...382 XANTREX FREEDOM XC PRO INVERTER...
Page 384: ...384 XANTREX FREEDOM XC PRO INVERTER...
Page 385: ...385 XANTREX FREEDOM XC PRO INVERTER...
Page 386: ...386 XANTREX FREEDOM XC PRO INVERTER...
Page 387: ...387 XANTREX FREEDOM XC PRO INVERTER...
Page 388: ...388 XANTREX FREEDOM XC PRO INVERTER...
Page 389: ...389 XANTREX FREEDOM XC PRO INVERTER...
Page 390: ...390 XANTREX FREEDOM XC PRO INVERTER...
Page 391: ...391 XANTREX FREEDOM XC PRO INVERTER...
Page 392: ...392 XANTREX FREEDOM XC PRO INVERTER...
Page 393: ...393 267 288 9 15 290 296 305 0 9 69 336 396 406 0 27 122 125 XANTREX FREEDOM XC PRO INVERTER...
Page 394: ...394 XANTREX FREEDOM XC PRO INVERTER...
Page 395: ...395 XANTREX FREEDOM XC PRO INVERTER...
Page 396: ...396 XANTREX FREEDOM XC PRO INVERTER...
Page 397: ...397 XANTREX FREEDOM XC PRO INVERTER...
Page 408: ......
Page 409: ......