156
CrossFire 8730 Switch Reference Guide, DOC-7047 v. 1.1
Monitoring the Network from the Statistics Menu
Assign Physical Drop Number subvector X'04' of the Change Parameters or the
Initialize Station MAC frame. Valid range is from 0x00000000 to 0xFFFFFFFF.
Join State
This field displays the present state of the Join FSM. Possible values are Not
Specified, Bypass, Registration, Lobe Test, Dup Addr Check, Dup Addr Det, Join
Complete and Await Notify.
Monitor State
This field displays the present state of the Monitor FSM. Possible values are Not
Specified, Operational, Transmit Beacon, Wire Fault Delay, and Int Test Wait.
Beacon Source Address
This field displays the source address used in the last Beacon MAC frame
transmitted or received.
Beacon UNA
This field displays the value of the UNA subvector X'02' used in the last Beacon
MAC frame transmitted or received. It will indicate the individual MAC address of
the sending ring station’s nearest active upstream neighbor (NAUN). The value
could be a valid individual MAC address or Unknown.
Beacon Physical Drop Number
Physical location of the sending ring station. This field displays the value of the
Physical Drop Number subvector X'0B' used in the last Beacon MAC frame
transmitted or received. Valid range is from 0x00000000 to 0xFFFFFFFF.
Event Status
This field displays the latest event status of the TXI interface. Possible values are
Insert REQ Rec, Insert RPS Rec, Report Error, Heart Beat Lost, Signal Loss,
Beacon Received, Remove, Internal Error, Station/CPort Err, Wire Fault, Claim
Received, Purge Received, Standby Received, Invalid SA, Act Mon Recvd, Phantom
Loss, and Dup Addr Det.
Summary of Contents for CrossFire 8730
Page 1: ...R e f e r e n c e G u i d e DOC 7047 1 1 CrossFireTM 8730 Fast Ethernet Translation Switch...
Page 2: ......
Page 3: ...CrossFire TM 8730 Fast Ethernet Translation Switch Reference Guide...
Page 6: ...iv CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1...
Page 14: ...xii CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1...
Page 28: ...14 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Introduction...
Page 146: ...132 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Switch Configuration...
Page 208: ...194 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Monitoring the Network with SNMP...
Page 220: ...206 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Abbreviations...
Page 232: ...index 12 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Index...
Page 233: ......