191
CrossFire 8730 Switch Reference Guide, DOC-7047 v. 1.1
Monitoring the Network with SNMP
addressee of a protocol message that is not properly authenticated. While
implementations of the SNMP must be capable of generating this trap, they must
also be capable of suppressing the emission of such traps via an implementation-
specific mechanism.
Enterprise specific traps - from OC8600.MIB
oc8600TsStackCfgChange
This trap is generated when there is a change in the stack configuration i.e. when
either a new switch is added to the stack or a switch leaves a stack.
oc8600TsNumSwitches indicates the current number of switches which are part of
the stack. The management station should update its stack information according to
the stack table.
oc8600TsStackStackMatrixChange
This trap is generated when the stack switches over from primary to secondary
Matrix or from secondary back to primary Matrix.
oc8600TsStackTempChange
This trap is generated when the temperature in a switch exceeds normal or returns
to normal.
oc8600sPowerSupply
This trap is generated when the status of the power supply units changes.
Per Port Traps
oc8600TsPortStrNFwdEntry
This trap is generated when a port automatically enters store and forward mode
when the error rate exceeds the threshold.
oc8600TsPortCfgLossTrap
This trap occurs when a port is disabled because it has exceeded its Configuration
Loss Threshold within the configured Sampling Period.
oc8600TsBeaconStart
This trap is generated when a port or a station local to a port begins to beacon. It is
sent out only when a ring status change indicates that a station is beaconing.
oc8600TsBeaconEnd
This trap is generated when the ring status change indicates that a ring is no longer
beaconing. This trap only occurs once when the status actually changes.
Summary of Contents for CrossFire 8730
Page 1: ...R e f e r e n c e G u i d e DOC 7047 1 1 CrossFireTM 8730 Fast Ethernet Translation Switch...
Page 2: ......
Page 3: ...CrossFire TM 8730 Fast Ethernet Translation Switch Reference Guide...
Page 6: ...iv CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1...
Page 14: ...xii CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1...
Page 28: ...14 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Introduction...
Page 146: ...132 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Switch Configuration...
Page 208: ...194 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Monitoring the Network with SNMP...
Page 220: ...206 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Abbreviations...
Page 232: ...index 12 CrossFire 8730 Switch Reference Guide DOC 7047 v 1 1 Index...
Page 233: ......