13.2 Connection plan
The Connection plan is a description of all the electrical connections from the Pelletronic heating controller:
Only an authorised installer may install and connect the
heating controller to the power supply.
Isolate the entire heating system from the power supply
before starting work on the heating controller.
Boiler outside sensor must be connected on
the first heating controller!
Terminals extra-low voltage zone
Terminals low voltage zone - 120VAC
X1A
Bus wiring
Bus
RS485
BRanf 1
Burner demand 1
X22
X1B
Bus wiring
Bus
RS485
M1
Mixer HC1 OPEN
X23–13/N
X2
Outdor sensor
AF
M1
Mixer HC1 CLOSE
X23–23/
N
X3
Boiler sensor
KF
BRanf 2
Burner demand 2 – BRanf
2
(Potencial free contact)
X24
X4
Flow sensor HC1
VL1
M2
Mixer HC2 OPEN
X25–13/N
X5
Flow sensor HC2
VL2
M2
Mixer HC2 CLOSE
X25–23/
N
X6
DHW sensor
WW
HK1
Heating circuit pump – HC1
X26
X7
AC upper sensor
PO
HK2
Heating circuit pump –
HC2
X27
X8
AC middle sensor
PM
Sol P2
Solar pump 2
X28
X9
AC lower sensor 1
SPU1
ZP
Return pump – Heat main
pump
X29
X10
AC lower sensor 2
SPU2
WW
Domestic hot water pump
X30
X11
Solar pump 1
OUT1
Sol P1
Solar pump 1
X31
PE 607 USA_FA 2.1
56
Summary of Contents for PELLEMATIC SmartXS
Page 29: ...Dismantling of the housing parts 29 Installation Manual PELLEMATIC SmartXS ...
Page 30: ...PE 607 USA_FA 2 1 30 Dismantling of the housing parts ...
Page 45: ...Suggested piping arrangement for combined operation 45 Installation Manual PELLEMATIC SmartXS ...
Page 49: ...Wiring diagrams 49 Installation Manual PELLEMATIC SmartXS ...
Page 50: ...PE 607 USA_FA 2 1 50 Wiring diagrams ...
Page 51: ...Wiring diagrams 51 Installation Manual PELLEMATIC SmartXS ...
Page 52: ...PE 607 USA_FA 2 1 52 Wiring diagrams ...
Page 96: ...PE 607 USA_FA 2 1 96 Pellet boiler cautionary markings ...
Page 97: ...Pellet boiler cautionary markings 97 Installation Manual PELLEMATIC SmartXS ...
Page 98: ......
Page 99: ......