12.3 Fuses - boiler controller
The control unit is protected against short circuits by fuses. There are 5 fuses in the Terminal Box at the rear
of the boiler and two fuses at the lower area on the main controller or FA.
D
Da
am
ma
ag
ge
e o
off p
prro
op
pe
errtty
y
If fuses are suspected of problems, take great care when
replacing any of them! Always replace fuses with fuses
of the correct rating and time delay.
1
F1: Fuse T10A
Fuse F1 is a time delay fuse, 10 amp and provides
protection for the Vacuum Turbine motor.
2
F2: Fuse T8A
Fuse 2 is a time delay fuse, 8 amp and is the pro-
tection for all other outputs from the main control-
ler or "FA".