4. Part Replacement
4.2.3.16 Regist roller Assy
(1) Open the scanner and the top cover.
(2) Remove the side covers L and R. (Refer to chapters 4.2.3.3 and 4.2.3.4.)
(3) Remove the MPT Assy. (Refer to chapter 4.2.3.15 (2).)
(4) Disconnect the cable .
(5) Remove the two screws (silver) and remove the gear cover .
(6) Disconnect the connector from the high voltage PCB. Remove the six screws
(silver) and remove the regist roller Assy by pulling it as shown by the arrow.