4. Part Replacement
(7) Remove the screw (silver) and disconnect the contact Assy Head . (Tool No. 1)
(8) Disconnect the two connectors and , and the FFC connector . Then remove
the two screws (silver) and the relay PCB (P6Y) . (Tool No. 1)
LCR
DENS
RCR
FUSERIN
FUSER
PUIF
EXIT
Relay PCB (P6Y)