4. Part Replacement
4.2.3.11 Top cover/Extension transport Assy
(1) Remove the top cover Assy. (Refer to chapter 4.2.3.10.)
(2) Remove the sixteen screws (black) and the screw (silver. Remove the cable cover
, the cable cover base , the top cover and the extension transport Assy .
(Tool No. 1)
(3) Disconnect the connectors of the respective blocks and remove the cable Assy
head .
Film contact
For K head
For RFID
For Y head
For M head
For C head