Oki Data CONFIDENTIAL
43967002TH Rev. 1
163 /
4. Part Replacement
4.2.3.9 PU PCB
(1) Remove the plate shield R. (Refer to chapter 4.2.3.7 (1) and (2).)
(2) Remove the plate shield F. (Refer to chapter 4.2.3.8 (3).)
(3) Remove the screw and remove the L-shape metal plate .
(4) Remove the four screws and the screw (black), and remove the HDD bracket
. At the same time, disconnect the cord from latch.
(5) Disconnect all connectors and the two screws (silver) . Remove the PU PCB .
(Tool No. 1)
× 4