4. Part Replacement
4.2.3.12 Shaft eject Assy (FU)/Shaft eject Assy (FD)
(1) Remove the scanner. (Refer to chapter 4.2.1.)
(2) Release the hook of the link arm , stay arm L and stay arm R .
(3) Remove the screw (silver) and disconnect the guide eject Assy upper .
(4) Remove the gear idle ejects and .
(5) Remove the two mold E-ring , and remove the shaft Assy eject (FU) and the
shaft Assy eject (FD) by bending them.
Note!
If the top cover is closed while the hooks of the stay arm L and R, and the
hooks of the link arm being released, the top cover can be damaged. Before
closing the top cover, engage the hooks of the respective parts to their original
positions. (Refer to Fig. XX.)
⑦
⑥
⑧
⑧
⑨
⑩