Thick cable
Thin cable
A square hole to draw the thick cable
①
①
②
③
③
⑤
⑤
④
④
View A
View A
4.2.15 Fuser Assy
Note!
Replace the Fuser-Assy by Assy unit.
It is forbidden for disassembling the Fuser-Assy, also, reusing the
disassembled Fuser-Assy.
(1) Take out the Frame-Assy-TR. (Refer to 4.2.2)
(2) Remove the Cover Assy Stacker. (Refer to 4.2.13)
(3) Remove the two screws (Silver)
①
. Remove the
Plate-Duct-Assy
②
.
(4) Remove the two screws (Silver)
③
and lift off Fuser-Assy
④
after
disconnecting two cables from it.
(5) Remove the Lever-Link-Fuser
⑤
.(Both side)
(6) Assembling is performed by the inverse procedure with removing.
Note!
Fuser-Assy
④
may be really hot, beware of handling.
(Note on removing / assembling)
1. Beware of not to touch the DC motor inattentively (Do not rotate the motor).
2. Install the Fuser-Assy
④
and Plate-Duct-Assy
②
carefully to avoid
cables from being caught.
3. Beware of not to damage the FFC cable when disconnect the thick
cable from Plate-Side-R-Assy.
4. Disconnect the FFC cable, when disconnect the thick cable. Beware of
not to harflock the FFC cable when connect the FFC cable.
4-17