4.3.18 Guide Eject Lower Assy
(1) Remove the Cover-Side-R and Cover–Side-L. (Refer to 4.2.4 / 4.2.5)
(2) Remove the CU-Board. (Refer to 4.2.6)
(3) Remove the Sheet-Insulation-CU. (Refer to 4.2.9)
(4) Remove the Cover-Eject. (Refer to 4.2.13)
(5) Remove the two screws (Silver : 8mm)
①
. Remove the
Cover-Cassette-
Rear Assy
②
and Guide-Eject-Lower-Assy
③
.
(6) Remove the post
④
. Remove the Separator-SB-FD
⑤
and Spring-
Separator_SB
⑥
.
(7) Remove the Lever-Exit-Sensor
⑦
and Spring-Sensor-Exit
⑧
.
(8) Remove the Exit-Sensor
⑨
.
(9) Assembling is performed by the inverse procedure with removing.
(Note on removing / assembling)
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Install Cover-Cassette-Rear Assy
②
carefully to avoid the FFC cable
from being caught.
A
A
①
①
②
③
④
⑤
⑦
⑧
⑨
⑥
FFC cable
4-20