2
2-56 Color Calibration
ES3640e MFP Color Guide - 56
When you click Start, the Measurements window appears.
Directions for measuring the patches appear in the Status area.
9. Place the ED-100 over the specified patch on the Measurement
Page, making sure to center the sample aperture over the patch.
Press Measure to take the measurement.
Note:
For a more accurate
measurement, place several plain
sheets of paper beneath the
Measurement Page to block
underlying colors from being read by
the instrument.
If you have specified multiple clicks
per patch, continue pressing Measure
to take the required number of
measurements. We recommend that
you move the ED-100 slightly after
each measurement while keeping it
within the patch circle.
Summary of Contents for ES3640eMFP