B
B-111 Importing Density Measurements
ES3640e MFP Color Guide - 111
Example of 1D Status T density for EFI 21 patch
page
This file format is used to specify the Status T density
measurements of the EFI 21 patch page. The value in the first
column is the patch number. The first patch must be 1 and the last
must be 21.
#!EFI 3
# EFI ColorWise 2.0 Data
type: 1DST21
# Cyan Magent Yellow Black
1 0.0300 0.0400 0.0200 0.0400
2 0.0600 0.0700 0.0800 0.0700
3 0.1000 0.1000 0.1000 0.1000
(…more data…)
20 1.6700 1.3400 0.8900 1.6700
21 1.7200 1.4300 0.9300 1.7500
Example of 1D Status T density for an arbitrary
page
This file format is used to specify the Status T density
measurements of a user-defined patch page. The value in the first
column is the ink/toner percentage of the patch. The first
percentage must be 0 and the last percentage must be 100. The
percentages must increase in between.
#!EFI 3
# EFI ColorWise 2.0 Data
type: 1DST
# percnt Cyan Magent Yellow Black
0.0000 0.0300 0.0400 0.0200 0.0400
0.3922 0.0600 0.0700 0.0800 0.0700
1.1765 0.1000 0.1000 0.1000 0.1000
(…more data…)
98.0000 1.6700 1.3400 0.8900 1.6700
100.0000 1.7200 1.4300 0.9300 1.7500
Summary of Contents for ES3640eMFP
Page 1: ......