2-52 Color Calibration
ES3640e MFP Color Guide - 52
9. Place the ES-1000 in
the calibration cradle,
and click OK.
The EFI Spectrometer
Measurement dialog
box appears.
Directions for
measuring the strips
appear in the Status
field.
Note:
For a more
accurate
measurement, place several sheets of plain white paper beneath
the Measurement Page to block underlying colors from being read
by the instrument.
10. Place the sample aperture in the white space at the start of the
specified color.
11. Press and hold the measure button and wait for a beep.
Note:
To hear a beep with a Windows compatible computer, you
must have a sound card and speaker(s) installed.
12. After you hear a beep, slide the ES-1000 at a slow but consistent
pace across the strip.
13. Release the button when all the patches in the strip have been
measured, and you have reached the white space at the end of
the strip.
When a strip is measured successfully, the cross hair moves to the
next color.
14. Repeat
until all the strips have been
measured.
Note:
You must take the measurements in the order outlined in
the Status field.
15. When all the patches have been read successfully, click Accept.