Option water cooling
Cooling water connections
G 1/8“
Cooling water data
see Section 2.6
Option air cooling
Power consumption
6.2 W
Volume flow
80 m
3
/h
TURBO.DRIVE 400
Supply voltage
24 V
(± 10%)
Residual ripple
< 3 %
Output
Voltage
0 - 24 V 3~
Power
160 W
Frequency
0 - 1500 Hz
When operating a SL 300
Nominal voltage
24 V
Max. power consumption
190 W
Max. peak current, input side
8 A DC
Required power output from the power supply
≥
200 W
Max. length of the DC cable (shielded)
at 3 x 1.5 mm2
5 m
at 3 x 2.5 mm2
20 m
Relay output rating
42 V, 0.5 A
Ambient temperature
during operation
5 - 45 °C
storage
- 15 - + 70 °C
Relative air humidity
5 to 85 % non condensing
Overvoltage category
II
Contamination grade
2
Temp. of the cooling surface
5 - 55 °C
For Part Nos. 800073V0004 /07
5 - 50 °C
Power consumption
≤
20 W
Type of protection
IP 20
Weight, approx.
0.5 kg
Description