2. STEP OFF Set
▌Power Switch ON
Turn on load and check load is in OFF MODE.
▌Press STEP Key.
▌Set [2. STEP OFF Set] by cursor key.
▌Press STEP Key.
▌Set STEP mode by cursor key. (INPUT ON or INPUT OFF Mode)
▌Press STEP Key to save setting value.
≫ Related Remote Interface Command
CYC:STEP:MODE:{1 | … | 100} OFF
Application :
CYC:STEP:MODE:1? Return value "OFF"
Step 1 OFF Check
CYC:STEP:MODE:1 OFF
Step 1 OFF Mode Setting
- 37 -
STEP
STEP
STEP