To set up the power supply for constant current (CC) operation, proceed as follows.
▌Turn on the power supply.
After turned on, check the power supply displays
▌Connect power and load(wire,condensor, motor) to the load.
▌Press Mode key and enter to CC Mode.
"OFF-ISET" will be displayed.
▌Press Range key.
There are Low range and High range in CC Mode.
▌set the range by cursor and encoder.
▌After finishing the whole setting, press input ON/OFF key.
CC Lamp will be on and If range is low, LO will be displayed.
If range is high, HI will be displayed.
≫ Related Remote Interface Command
mode:{<VOLT>,<CURR>,<RES>}
CURR{<current>}
CURR:RANG:{<L>,<H>}
INPUT{OFF|ON}
Application 1:
INPUT OFF
Disable the input
MODE:CURR
CC Mode Setting
CURR:RANG L
LOW Range Setting
CURR 10
Set Current Value
INPUT ON
Able the input
Note
1.Left cursor key controls the increase of voltage range, right cursor key controls the
decrease of current range.
2. Readback Display is the status that display the output voltage and current in display panel.
3-2. Constant Current Operating (CC)
- 15 -
MODE
RANGE
IN ON/OFF