To set up the load for constant Resistance operation, proceed as follows.
▌Turn on the load.
After turned on, check the load is in Off Mode.
▌Connect power and load(wire,condensor, motor) to the load.
▌Press Mode key and enter to CR mode.
On the left bottom in display panel, "OFF-RSET" will be displayed.
▌Press Range key.
There are Low,Mid ,High Range.
▌In order to set the resistance value, use the right cursor key and
encoder knob.
▌After setting. Press Input ON/OFF Key and automatically CR Lamp
will be on.
If Range setting is low, LO will be displayed in the right bottom.
Mid will be "MI", High will be "HI".
≫ Related Remote Interface Command
mode:{<VOLT>,<CURR>,<RES>}
RES{<res>}
RES:RANG {<L>,<M>,<H>}
INPUT{OFF|ON}
Application1:
INPUT OFF
Disable the input
MODE:RES
CR Mode Setting
RES:RANG L LOW Range Setting
RES 10
Resistance value Setting
INPUT ON
Able the input
3-3. Constant Resistance Operating (CR)
- 16 -