DIAM4200 ©2018 AUGIER SA.
6021642 DIAM4200 5 to 20KVA rev 1-8.docx
II-35
II.2.2.1 IEC Multiwire remote control (IEC type CCRs only):
This board is used for all standards based on IEC standard (STNA...) or if the relays board type FAA is
not needed.
II.2.2.1.1
Terminal block T1 (Inputs and brightness indication)
N°
Function
Type
1
B0 control
Input voltage or Contact with respect to C
2
B1 control
Input voltage or Contact with respect to C
3
B2 control
Input voltage or Contact with respect to C
4
B3 control
Input voltage or Contact with respect to C
5
B4 control
Input voltage or Contact with respect to C
6
B5 control
Input voltage or Contact with respect to C
7
B6 control
Input voltage or Contact with respect to C
8
B7 control
Input voltage or Contact with respect to C
9
“ON” control
Input voltage or Contact with respect to C
10
Aux1 control
Input voltage or Contact with respect to C
11
Aux2 control
Input voltage or Contact with respect to C
12
Aux3 control
Input voltage or Contact with respect to C
13
Aux4 control
Input voltage or Contact with respect to C
14
C
Common to Pin1 to Pin 13 inputs (note 2)
15
NOT USED
16
NOT USED
17
NOT USED
18
NOT USED
19
NOT USED
20
NOT USED
21-22
B0 return (On)
Open collector (note 3)
23-24
B1 return
Open collector (note 3)
25-26
B2 return
Open collector (note 3)
27-28
B3 return
Open collector (note 3)
29-30
B4 return
Open collector (note 3)
31-32
B5 return
Open collector (note 3)
33-34
B6 return
Open collector (note 3)
The remote control
protection fuse
is marked as PFU2 on the interface board (5x20mm 250V/500mAT)