DIAM4200 ©2018 AUGIER SA.
6021642 DIAM4200 5 to 20KVA rev 1-8.docx
II-41
II.2.2.6 Example of FAA wiring : EXTERNAL 48Vdc
-
According AC150/5340-30, and only for control lines
-
3 Steps CCR
-
Wiring remote control voltage configuration):
II.2.2.7 FAA Multiwire remote control with INTERNAL 20 to 60Vdc control supply
When delivered, the CCR is configured in factory as :
-
“Internal” power supply:
see:
Wiring remote control voltage configuration
-
“ON order”
see:
Operating modes for multiwire (FAA & IEC) remote control :
- Default brightness B1 (2.8A)
- 1, 3 or 5 brightness, as ordered and indicated in the part number (see at the end
The 34-pin terminal blocks making up the inputs and outputs for remote control are situated at the back of
the CCR.
II.2.2.7.1
Inputs (contacts free of voltage only) :
Terminal
T.Bloc
Function
FAA label
Pin Type
1
T1
B1 control
B1
Contact or short-circuit with C
2
T1
B2 control
B2
Contact or short-circuit with C
3
T1
B3 control
B3
Contact or short-circuit with C
4
T1
B4 control
B4
Contact or short-circuit with C
5
T1
B5 control
B5
Contact or short-circuit with C
6
T1
“ON” control
CC
Contact or short-circuit with C
7
T1
Circuit 1 control (*)
Contact or short-circuit with C
8
T1
Circuit 2 control (*)
Contact or short-circuit with C
9
T1
Circuit 3 control (*)
Contact or short-circuit with C
10
T1
Circuit 4 control (*)
Contact or short-circuit with C
11
T1
Circuit 5 control (*)
Contact or short-circuit with C
12
T1
Aux 1 control (**)
Contact or short-circuit with C
13
T1
Aux 2 control (**)
Contact or short-circuit with C
14
T1
C
CCI
Common to Pin1 to Pin 6 inputs
DIAM4200 L828/L829
2.2nF