SAMM
User Manual
52
6.4.3 Teledyne BlueView 2D Multibeam Imaging Sonar
Similar to M3 interfacing, SAMM interfaces with the BlueView family of 2D imaging sonar
systems by receiving data and metadata strings from the sonar software, ProViewer. ProViewer,
however, must be configured to push data to SAMM. The following instructions and screenshot
were valid with ProViewer 4 at the time of this writing, but may not be up to date. Please consult
the ProViewer manual for the most accurate instructions.
Figure 42. ProViewer NMEA Panel
Figure 43. ProViewer Data Streaming Configuration
To interface with ProViewer:
1. Launch ProViewer version 4.3 or newer and connect to the sonar as usual.
Configure NMEA settings via the NMEA(GPS) tab in the application settings menu
(Figure 42). SAMM requires GGA, HDT, and ZDA inputs to be configured.
Configure ProViewer for streaming data to SAMM by clicking on the
Application
settings
icon, clicking on the AppEx tab, Click the checkbox next to
RTheta Images,
Nav. Data and Pan/Tilt Data
(match Figure 43). If you are running SAMM on a different
computer than ProViewer, enter the IP address in the field. Otherwise, enter the local IP
address (192.168.1.3 if using the IP address suggested in the ProViewer manual). Click
Show Advanced Settings
if the IP address in unavailable.
2. Turn on the data broadcasting by clicking the AppEx broadcast on icon in ProViewer.