4-10
Manual Calibrations
◆
34-inch (900 mm) calibration
— prints a 34-inch (or
900 mm) test pattern so you can verify its length with
an accurate metal ruler. Cut the pattern from the media
web, then measure and adjust the media advance as
needed until the pattern is exactly 34 inches (900 mm)
long.
◆
10-inch (250 mm) calibration
— prints a 10-inch (or 250
mm) test pattern so you can verify its length with an
accurate metal ruler. This is not as precise as the 34-inch
(900 mm) calibration, but it uses less media. Measure
and adjust the media advance as needed until the pat-
tern is exactly 10 inches (250 mm) long.
Tip
To avoid cutting the 10-inch (250 mm) pattern from
the media web, copy the marks from the printed
pattern to the long edge of a letter-size (or A4)
sheet of paper. Then measure the transferred marks
and adjust the media advance as needed until the
marks are exactly 10 inches (250 mm) apart.