AutoTune
4-5
Quality Check
When you run AutoJet manually, the software notifies you if
there are any jet or alignment problems so that they can be
addressed. When AutoTune runs AutoJet at scheduled intervals,
you can use the Quality Check feature to handle AutoJet errors.
When Quality Check is enabled, if any missing jets are found
that are not substituted by a working jet, or if the BiDi and
Media Feed calibrations have not been performed, the operator
can be alerted by the control panel.
1.
On the Front Page screen, press the
(Menu) key to enter
the menu system.
2.
Press the
key repeatedly to highlight
Printer Settings.
3.
Press the
(Menu In) key display the
Printer Settings
menu.
4.
Press the
key repeatedly to highlight
Quality Check.
5.
Press
(Proceed).
The control panel displays the Quality Check options.
◆
Attended Mode
— user must press
(Proceed) to
acknowledge the error and print the job (if one is pend-
ing), or
(Cancel) to cancel printing.
◆
OFF
— no quality check is performed, all jobs will print.
6.
Select a Quality Check option.
7.
Press the
(Menu Out) key repeatedly until the Front Page
screen is displayed. Press the Online/Offline button to return
the printer to the Ready state.
Summary of Contents for CS7075
Page 1: ...Oc CS7075 Oc CS7100 User Manual for Oc UV curable inkjet printers 0706341 Rev B...
Page 8: ...viii...
Page 25: ...Workflow Overview 1 13...
Page 28: ...1 16 Workflow Overview...
Page 38: ...1 26 Special Features...
Page 100: ...3 44 Media Wizard...
Page 107: ...Auto Calibrations 4 7 Fig 4 1 Auto calibration patterns and reports...
Page 128: ...4 28 Linearization...
Page 138: ...5 10 Recover Missing Ink Jets...
Page 176: ...B 16 Diagnostics...
Page 177: ...Index 1 Index...
Page 182: ...Index 6...