37
1568911, Edition 2019-04, Version 0
8
Mounting the Ceiling Tube to the Threaded Bolts of the Interface Plate
EN
Figure 21: Mounting a ceiling tube
8.2 Mounting a ceiling tube
(See "Figure 21")
The Figure only shows a simplified representation of the flange⑥ with
ceiling tube to be mounted to the threaded bolts. Further components
pre-assembled to the flange⑥, such as the motor arm, extension arm,
cables, etc. are not represented.
Risk of parts falling off
Make sure that no-one is standing underneath the compo
-
nents of the pendant system whilst it is being installed.
1. Securely fasten the flange⑥ of the ceiling tube with motor arm
4
or the extension arm with motor arm
5
or the XL extension arm
with motor arm
5
to a suitable lifting device and position it under
the threaded bolts M16① of the interface plate
1
.
NOTE – Position of the flanges on the Duo version
•
The flanges have a chamfered surface⑦ in order to ensure that they
can be mounted at the same height.
•
Mount the flanges such that the chamfered surfaces⑦ are aligned
towards each other as illustrated in the Figure.
2. Insert the flange⑥ of the ceiling tube with motor arm
4
or the ex
-
tension arm with motor arm
5
or the XL extension arm with motor
arm
5
into the 6 threaded bolts M16① of the interface plate
1
.
3. Remove the previously attached adhesive or elastic tape from the
threaded bolts①.
4. For each threaded bolt M16①, place 1 plastic insulating disc① (as
illustrated in the Figure) in such a way that the flat washer with an
external diameter of 34mm③ (see arrow in the detailed representa
-
tion in the Figure) sits in the plastic insulating disc①.
5. For each threaded bolt M16①, place 1 flat washer with an external
diameter of 34mm③, 1 spring disc④ and 1 hexagonal nut M16⑤.
6. Component on the interface plate
1
:
•
Align the Single version as described in Chapter 8.3 on Page 38.
•
Align the Duo version as described in Chapter 8.4 on Page 40.
WARNING