29
1568911, Edition 2019-04, Version 0
6
Mounting Threaded Bolts to the Interface Plate
EN
Figure 13: Mounting the upper insulations to the threaded
bolts
6.2.4 Mounting the upper insulations to the threaded bolts
(See "Figure 13")
1. For each threaded bolt M16① screw a hexagonal nut M16② onto
the threaded bolts M16①.
2. Adjust the distance between the hexagonal nuts M16② and the in
-
terface plate
1
:
•
L = LG – 95mm (min.110mm / 150mm)
3. Screw the hexagonal nuts M16② onto the threaded bolts M16① at
the calculated distance L.
4. Using a digital spirit level, align the hexagonal nuts M16② in a hori
-
zontal position.
5. Place 1 flat washer with an external diameter of 34mm③.
6. Place 1 plastic insulating disc④ (as illustrated in the Figure) in such
a way that the flat washer with an external diameter of 34mm③
(see arrow in the detailed representation in the Figure) sits in the
plastic insulating disc④.
7. Using an adhesive or elastic tape, attach the plastic insulating
disc④ to the threaded bolts M16①.
8. Continue the installation as described in Chapter 7 on Page 32 or
Chapter 8 on Page 36.