![NTT docomo FOMA N706i Instruction Manual Download Page 502](http://html1.mh-extra.com/html/ntt-docomo/foma-n706i/foma-n706i_instruction-manual_1715414502.webp)
49
AT&W
n
Stores the current settings.
Only
n
= 0 can be specified (can be omitted).
AT&W0
OK
AT&W
OK
AT&W?
ERROR
AT&W
=
?
ERROR
AT
*
DANTE
Displays the FOMA
terminal signal reception
level.
0
:
FOMA terminal signal reception level is displayed
as out of area.
1
:
FOMA terminal signal reception level is 0 or 1
bar.
2
:
FOMA terminal signal reception level is 2 bars.
3
:
FOMA terminal signal reception level is 3 bars.
AT
*
DANTE
*
DANTE:3
OK
AT
*
DANTE
=
?
*
DANTE:(0-3)
OK
AT
*
DGANSM=
n
Sets the reject/permit mode
setting for the packet
incoming call. This
command is effective for
those incoming packet calls
after the setting command
is input.
n
= 0
:
Disables the incoming call reject (AT
*
DGARL)/permit setting (AT
*
DGAPL)
(initial value).
n
= 1
:
Enables the incoming call reject
setting.
n
= 2
:
Enables the incoming call permit
setting.
AT
*
DGANSM?
:
Displays the current setting.
AT
*
DGANSM=0
OK
AT
*
DGANSM?
*
DGANSM:0
OK
AT
*
DGAPL=
n
[,cid]
Sets APN, which permits
incoming packet calls, by
using <cid> parameter
defined by
+CGDCONT
n
= 0
:
Adds the APN defined by <cid> to
incoming call permission list.
n
= 1 : Deletes the APN defined by <cid>
from incoming call permission list.
If <cid> is omitted, this will apply to all cid.
AT
*
DGAPL?
:
Displays incoming call permission
list.
AT
*
DGAPL =0,1
OK
AT
*
DGAPL?
*
DGAPL:1
OK
AT
*
DGAPL =1
OK
AT
*
DGAPL?
OK
AT
*
DGARL=
n
[,cid]
Sets APN, which rejects
incoming packet calls, by
using <cid> parameter
defined by
+CGDCONT
n
= 0 : Adds the APN defined by <cid> to
incoming call rejection list.
n
= 1 : Deletes the APN defined by <cid>
from incoming call rejection list.
If <cid> is omitted, this will apply to all cid.
AT
*
DGARL?
:
Displays incoming call rejection list.
AT
*
DGARL =0,1
OK
AT
*
DGARL?
*
DGARL:1
OK
AT
*
DGARL =1
OK
AT
*
DGARL?
OK
AT
*
DGPIR=
n
This command validates
the setting for notifying
Caller ID when sending/
receiving packet
communication.
Even in the dial up network
setting, you can also add
186 (notify) or 184 (not
notify) to the access point
number. (p.36)
n
= 0 : Uses APN as it is (initial value).
n
= 1 : Uses APN by adding "184". (Caller
ID is always not sent.)
n
= 2 : Uses APN by adding "186". (Caller
ID is always sent.)
AT
*
DGPIR?
:
Displays the current setting.
AT
*
DGPIR =0
OK
AT
*
DGPIR?
*
DGPIR:0
OK
AT
*
DRPW
Displays the indicator value
of the receiving power of
the FOMA terminal.
−
AT
*
DRPW
*
DRPW:0
OK
AT
*
DRPW=?
*
DRPW:(0-75)
OK
AT+CAOC
Inquires for the current
charge.
−
AT+CAOC
+CAOC:"000014"
OK
AT command
Outline
Parameter/description
Command execution example
Summary of Contents for FOMA N706i
Page 90: ......
Page 172: ......
Page 226: ......
Page 234: ......
Page 244: ......
Page 292: ......
Page 308: ......
Page 356: ......
Page 389: ...387 Continued on next page Appendix External Devices Troubleshooting Reading Reading Reading...
Page 425: ...423 Appendix External Devices Troubleshooting Memo...
Page 426: ...424 Appendix External Devices Troubleshooting Memo...
Page 427: ...425 Index Quick Manual Index 426 Quick Manual 440...
Page 440: ...438 Index Quick Manual Channel list screen 236 TV link list screen 239 1Seg screen 237...
Page 441: ...439 Index Quick Manual...
Page 515: ...Kuten Code List...