APOT:
This is a variation of REL2 and is the same system that is used by some other existing popular control surfaces.
A message with value 0+n is sent out for every clockwise step (increment) and a message with value 64+n is sent out
for every anti-clockwise step (decrement). The value n will equal 1 when you rotate the encoder slowly and increases as
you rotate the encoder faster.
Additional options for buttons only:
ON/OFF:
Control value displayed as either ON or OFF. The low value setting determines the ON value and the high value
setting determines the OFF value. This is best suited to a bi-state parameter where you want to see whether it is in an
on or off state, e.g. phase reverse on a mixer channel.
LED:
This is like ON/OFF except that nothing is displayed when the control is in an OFF state (rather than ‘OFF’ being
displayed as with ON/OFF).
Additional option for when
Control
is set to ‘NoContrl’:
LABEL:
If a control is not assigned to send a MIDI message then generally no information will be displayed for it in Play
mode and there will be a blank space for it on the display. You can, however, use that blank space to display up
to 8 characters (on the top line) by setting
DispType
to ‘LABEL’. If this is set, the control name will be displayed, even
though the control is not assigned to anything. You can edit the control name by pressing PAGE UP when in Edit Mode.
See page 51 for further information on editing control names.
LowVal (Low Value) and HighVal (High Value):
These options allow you to set the upper and lower limits of the control
value. By default, the Low Value will be set to the lowest possible value and the High Value will be set to the highest
possible value. In this case, the control will affect a parameter throughout its whole range. Adjust these settings if you want
the control on the SL Compact to affect a parameter through only part of its range.
The range of values allowed for both of these settings will depend on the
DispType
setting as follows:
DispType
Range for LowVal and HighVal settings
0-127
0 to127
-64/+63
-64 to +63
REL1
Not available
REL2
Not available
0-16K
0 to 16383
APOT
Not available
ON/OFF
0 to127
LED
0 to127
With an encoder, the control value will scale from the Low Value to the High Value as you rotate it clockwise. Consequently if
you want the control value to increase as you rotate the encoder clockwise, make sure the High Value is larger than the Low
Value. If you want the control value to decrease as you rotate the encoder clockwise (inverted action), make the Low Value
larger than the High Value. This also applies to the pitch and mod wheels and the expression pedal.
For buttons and trigger pads, the Low Value and High Value should be set in conjunction with the
BtnType
(Button Type)
setting. See page 50 amd 51 for further information.