Operation OEM6 Cards and Enclosures
Chapter 4
OEM6 Family Installation and Operation User Manual Rev 12
59
4.3.2
Rover Station Configuration
At the rover station, enter the following commands:
serialconfig [port] baud [parity[databits[stopbits[handshaking[break]]]]]
interfacemode port rx_type tx_type [responses]
For example, if COM2 was connected to the correction source:
RTK Automated Correction Detection
interfacemode com2 auto none off
RTCA
interfacemode com2 rtca none off
RTCAOBS2
interfacemode com2 rtca none off
RTCM V2.3
interfacemode com2 rtcm none off
RTCM V3
interfacemode com2 rtcmv3 none off
RTCM V3 with GLONASS
interfacemode com2 rtcmv3 none off
CMR+
interfacemode com2 cmr none off
CMR
interfacemode com2 cmr none off
(same as CMR+)
NOVATELX
interfacemode com2 NOVATELX none off
4.3.3
ALIGN
®
Heading Master and Remote Configurations
This section provides instructions for setting up a master station with an ALIGN capable rover receiver for
applications that require heading output. Refer to
APN-048 ALIGN Overview and Setup
, available at
Automatic Set Up for Direct-Wire Connection between Master and Rover via COM2
The
ALIGNAUTOMATION
command must only be sent to the rover.
ALIGNAUTOMATION ENABLE
or
ALIGNAUTOMATION ENABLE COM2 230400 10 ON