OEM615 Technical Specifications
Appendix A
OEM6 Family Installation and Operation User Manual Rev 12
119
INPUT/OUTPUT DATA INTERFACE
COM1
Electrical format
LVTTL
Bit rates
a
2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800
or 921600 bps. See
Signals supported
COM1_Tx, COM1_Rx
Electrostatic discharge protection
Yes
COM2
Electrical format
LVTTL
Bit rates
a
2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800
or 921600 bps. See
Signals supported
COM2_Tx, COM2_Rx
Electrostatic discharge protection
No
COM3
Electrical format
LVTTL
b
c
Bit rates
a
2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800
or 921600 bps. See
Signals supported
COM3_Tx and COM3_Rx
Electrostatic discharge protection
No
CAN BUS
D
Electrical format
LVTTL (requires external CAN transceiver)
Bit rates
1 Mbps maximum. CAN Bus throughput is determined by slowest device on
the bus
Signals supported
CAN1 and CAN2
USB
Electrical format
Conforms to USB 2.0
Bit rates
Full-speed USB
Signals supported
USB D (+), USBD (-)
ETHERNET
Physical Layer
None
a. Baud rates higher than 115,200 bps are not supported by standard PC hardware. Special computer hardware may be
required for higher rates, including 230400 bps, 460800 bps and 921600 bps.
b. COM3 is disabled by default. See
Section 4, OEM6 Card Default Serial Port Configurations
c. Event2 is enabled by default, but is multiplexed with CAN1. CAN functionality must be disabled for Event2 to work
properly. See
Section 4, OEM6 Card Default Serial Port Configurations
on page 39 for details
d. CAN Bus behavior must be asserted through the NovAtel API software. See
Section 4.10.2, CAN Bus (not available on the
on page 74 for further details. See also